Weighing tolerances can be defined for all items, a specific item or a weighing tolerance group

| Field | Description |
|---|---|
| Type | Here you can define if you want the setup to be valid for all articles, one article or a weight tolerance group. The weighing tolerance group is assigned on the article card. |
| Code | Depending on the type selected, either an article number or weighing tolerance group can be entered here. For the type = all articles the field remains empty. |
| Lower tolerance % | A value for the permitted lower percentage deviation of the sample weight can be entered here. The valid value is then transferred to the production rule line and from there to the production order and weighing order. |
| Upper tolerance % | Here you can enter a value for the permitted upper percentage deviation of the initial sample weight. The valid value is then transferred to the master batch record line and from there to the production order and weighing order. |